Description
Easy to Install Enphase IQ 7+ Interactive Inverter • Lightweight and simple • Faster installation with improved, lighter two-wire cabling, Enphase IQ7+ Grid Inverter • Built-in rapid shutdown compliant Efficient and Reliable • Optimized for high powered 60-cell and 72-cell modules • Highest EU efficiency of 96.5% • More than a million hours of testing • Class II double-insulated IP67 enclosure Smart Grid Ready • Complies with advanced grid support, voltage and frequency ridethrough requirements • Envoy and Internet connection required • Configurable for varying grid profiles
Enphase IQ 7+ Microinverters | |
INPUT DATA (DC) | IQ7PLUS-72-2-US |
Commonly used module pairings¹ | 235 W – 440 W + |
Module compatibility | 60-cell/120 half-cell and 72Cell/144 half-cell PV modules |
Maximum input DC voltage | 60 V |
Peak power tracking voltage | 27 V – 45 V |
Operating range | 16 V – 60 V |
Min/Max start voltage | 22 V / 60 V |
Max DC short circuit current (module Isc) | 15 A |
Overvoltage class DC port | II |
DC port backfeed current | 0 A |
PV array configuration | 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit |
OUTPUT DATA (AC) | IQ 7+ Microinverter |
Peak output power | 295 VA |
Maximum continuous output power | 290 VA |
Nominal (L-L) voltage/range² | 240 V / |
Maximum continuous output current | 1.21 A (240 V) 1.39 A (208 V) |
Nominal frequency | 60 Hz |
Extended frequency range | 47 – 68 Hz |
AC short circuit fault current over 3 cycles | 5.8 Arms |
Maximum units per 20 A (L-L) branch circuit³ | 13 (240 VAC) 11 (208 VAC) |
Overvoltage class AC port | III |
AC port backfeed current | 18 mA |
Power factor setting | 1.0 |
Power factor (adjustable) | 0.85 leading … 0.85 lagging |
[row] [col span__sm=”12″]
EFFICIENCY@240 V @208 V
Peak efficiency 97.5 % 97.3 % CEC weighted efficiency 97.0 % 97.0 %
MECHANICAL DATA
Ambient temperature range -40ºC to +65ºC Relative humidity range 4% to 100% (condensing) Connector type MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions (HxWxD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor
FEATURES
Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. [/col] [/row]
Reviews
There are no reviews yet.